Performance profile WB 18/76
The performance of Taborsky acoustic profiles has naturally been tested in a laboratory. By means of the Alpha Cabin test, it was possible for the products TR 35/207 and WB 18/76 to be tested for their sound absorption capacity. The determined laboratory values approximately reflect the performance of the product.
According to EN 13501-1, the fire behaviour of the trapezoidal profile and corrugated sheet together with the acoustic membrane is classified as A2-s1, d0.
Acoustic profile WB 18/76
This acoustic profile is a WB 18/76 corrugated profile.
The perforated metal profiles have the CE mark according to EN 14782 in compliance with the Construction Products Regulation.
Areas of intended use include self-supporting ceiling and wall cladding elements for interior areas.
The profile is mounted as a negative layer for the ceiling and wall.
This means that side B is the visible side with the 25 mµ polyester coating.
The acoustic membrane has been attached to side A.
The following construction arrangements were tested:
- Alpha cabin
- Standard PSA D49 1977
- Frequency: 400 - 10.000 Hz
- Volume: 6,44 m3
- Sample: 1,2 m2
Test results
The results of the tested constructions have been illustrated in the diagram below:
Overview Acoustic profiles
- Acoustic profiles
- Profile variants
- Perforation & acoustic membrane
- Performance profile TR 35/207
- Performance profile WB 18/76